Added support for Hunter Well Science Multifinger Caliper tools |
Spartek Accoustic Density with RTD support |
Fix bug in FDP tool module software that was inhibiting user from making multipoint calibrations |
Spartek SRO tool/telemetry support updated for used initiated tool configuration |
For tools with multiple instances, all available serial numbers were not always shown in tool string editor. |
Titan telemetry enhanced validation of Gowell embedded frames |
Hotwell/Wellsun updates for RBT data transform |
Inclinometor tool software now has optional filters for computed outputs such as deviation |
Enhanced support for Benchmark AMS panels: 9600 or 38400 baud; panel depth now changes with Warrior. |
Fix LAS and CSV 'Cancel at current depth' option when exporting live dataset - stop depth was not getting calculated correctly. |
Fix bug sometimes preventing generation of composite logs or drag run profiles when multiple shot tables exist in the same run. |
Fix bug causing depth errors when depth-shifted data is recalculated or extracted. |
Add option to FlowVelocity for injection well calculations. |
ASCTEL bug fix correcting the "Kerr" communication options |
Fix hot var scroll setting. Increase size of hot var dialog. |
Prestemp tool module software will cater to temperature outputs based on the QD pressure type algorithm. |
AuxPS device (Auxialliary power) support for SDS version 2 board (OPAQ) controlling PS1 for caliper motoring |
Gowell Caliper mtc files now have optional terms that can override defaults for DEVI output calculation |
Correct the 3 axis inclination calculation in INCL software |
Can copy a tool to a new name from tools editor. |
Add option to setup screen for automatic file naming. When exporting a live pass, another button will show up that will enable the user to cancel the export at the current log depth. |
Inclinometer tool module has new calibration type option (inclined calibration points with vertical reference). Additionally there is an optional RB Offset calibration to correct for RB reading with a reference point (caliper finger 1 for example). |
Allow to edit API code for DEPTH,TIME for LAS export. |
Fix 'Blue View Compatible' tiff creation for 32bit versions. |
Support for new CBL1 R10 Filter board |
Support for new Hotwell radial bond, multifinger caliper, and production logging tools |
Model Specific option for Tel ID added to FDP, CWH and CFB modules |
When restoring a configuration from Warrior 7, each service and tool will be restored individually. |
Sentinel HASP version 6.62 driver update - Fix for 'Driver Version mismatch' error. |
Well objects - no limit to number of depth intervals per object. Save last object ratio to be used as default for next time. |
Enabled vertical annotations from annotation editor. |
CSV template could include a signature curve that would break an LAS export. |
Add zoned scale changes for digital distributable. |
Fix for Signature and VDL plots - plots with nonzero offset not calculated correctly. |
Fix for extra long tiff files on 32bit installs. |
Fix CYSDA surface data acquistion module sample recording issue |
Added multi-line annotations. Annotation editor can accept carriage returns for line breaks within an annotation. Otherwise a long annotation will be wrapped when the text reaches the left or right border. |
Warrior Export - dialog is resizeable. Can clear default sample rate. |
Tool string editor - fix issue with removing/changing serialized accessory tools. |
Added BlueView Compatible option for Tiff LZW from Tiff Setup dialog. If your particular viewer cannot open your tiff file, then try this option. |
Global Build
Added support for Pioneer Petrotech PPS71 SRO tool/telemetry support |
GOWell multifinger caliper tool mtc files can have optional relative bearing (RB) offsets declared that will initialize the RB calibration offset used in processing |
New XYPlot. Setup procedure is slightly different. See Help from XYPlot for more details |
Pdf and tiff now have seperate horizontal and vertical resolutions. If you don’t edit anything then the resolutions are equal as they were before the change was made. For example, the Printrex 920 resolution is 300x200, so to make an image compatible with that printer it would need to have similar resolutions. |
Updates for Probe (PTX) scripted telemetry for 32 bit channels, masking available |
Updated support for Titan NextGen telemetry to have user scripted commands available from the device monitor |
Correct PLL multiplier options for PIP panel |
24 bit channel support for Probe scripted telemetry |
From Format Editor -> Layout : Can edit custom layout/grid for current format or all layouts. Made two seperate menu items to clarify what layout is being edited. |
Bug fix to conversion factors for variable units of flow measurements (vuFLOW). Conversion between BPD, BPM, M3D were scaled incorrectly |
Bypass rate output, calculation based on WHFLOW1 (pumping pressure), LSPD (cable speed), Casing OD and Casing thickness |
Warrior gauge updates: Numeric gauge will now honor the background color, so some gauges may start up with a white background that were gray before. Use the gauge properties to set the background color. You can now select the font size in addition to the font style and override the number of characters to determine the font size. You can set a default font for all gauges from the Warrior Control Panel -> Acquisition tab. |
Added option to multiarm IMG module for displaying image to scale. With this option, image 3D and potato plots will change size as different sized casing are logged rather than auto-scaling the image. |
Global Build
Database Utilities - resizeable dialogs for Alias, Differential, Correlation Curves, Depth Shift, Automerge, Rename. |
Mathpack - fix time log outputs. |
XY Caliper: CALA (Average Caliper) logged range is now correct; the system hang-up at the end of a recaclulation has been corrected. |
SDSTEL support for memory frame definitions |
Database select dialog now resizeable for longer database/dataset names. |
Remove watermark from pdf documents. |
Resizeable database select dialogs - handle long names better. |
SP Process option added to DELOG tool module. The default is "No", the tool configuration should now add the SP software module and service configuration be updated with "spoffset" and "spcalibrate" in the SDSTIP options for extra funcionality |
Tracer detectors option for output units (GAPI, cps or None) |
Support for new Deteq ELOG tool with directional data |
Fixes for the SIMPLEC RAG service (uses monocable option) |
Updated WAMNCH telemetry services to offer downlink slider |
Updated Katwell telemetry monitor to control switchable uplink baud rate |
Sentinel HASP version 6.56 for Windows 8 support. |
Fix error message during Autobackup. |
Fix issues with Spartek PLtelemetry utilizing 16 sensor channels and self identifying centralizers |
Add CSV (Comma Seperated Value) export option to Warrior Export program. |
PXD Boot Loader enhancements |
Control Panel External Power Supply type selection (for appropriate hardware) added to Acquisition Configuration |
Spectral Gamma Ray tool software using new monitor, supporting preliminary AlphaNeutronics tool type. Raw window count outputs now available (specific tool types) |
Support for KatWell Magnetic Thickness Tool |
Support for Permaworks PTS01 modified telemetry frame |
Support for Titan Compensated Neutron (4ATM) |
Enhancement to allow serial port sharing between devices such as ASCTEL and SERMON |
Added support for Kuster PT tool telemetry frame |
JPT/GOWell TSGT telemetry updates for sequential frame index checking/reporting |
Fix ability to add live pass to plot job. To cancel a live hardcopy from Interactive Plot, select File -> 'Abort the current log plot' from Presentation Plot. |
Titan "Next Gen" user configurable telemetry initial support (tested with 8 sector bond tool, GR-CCL, GOWell 40 arm caliper) |
USR tool module software updated for optional Verification Survey References and Master Verification without Master Calibration |
Fix issue with Probe OH Compensated Neutron missing calibration terms from report. |
Update Probe Hi-res Dual Laterolog to include before/after verifications |
Multifinger Caliper raw sensor readings (non temperature corrected) available for calibration reports. |
Applied Freepoint Tool, external power supply support. |
Format Editor has simple interface for lists of curves (for example, R1, R2, R3, ... R40 now via R*). |
Kuster Telemetry Monitor to more easily visualize tool synchronization. |
Updated Warrior USB device drivers (Cypress 3.04.0007.0000) |
Slider gain control available for digital CCL signals, configured in the tool module setup. |
Katwell Telemetry support for multifinger caliper tools, magnetic thickness tools, gyro tool, GR-Temp tool. |
ACE 1000 Telemetry support for Open Hole logging tools. |
Add selectable unit for porosity - decimal or percentage. |
Hunter Well Service PFMT Telemetry support. High Temp Production Logging. |
The Warrior 8 release includes many new features incuding support for Unicode, unlimited database size, and 64bit capabilities.
Other new features include:
* Requires separate license
Warrior 8 databases cannot be read by previous versions of Warrior, but Warrior 8 can read older databases. |
Windows XP:
The minimum operating system supported is Windows XP Service Pack 2. Known issues on Windows XP: Microsoft has updated the list of third-party certification authorities that are trusted by Windows but on Windows XP this update is not installed automatically. The user must download and install the update package (see http://support.microsoft.com/kb/931125). Without this update, Warrior programs may give an 0x800b010a error when starting as the system is unable to verify the digital signature of certain system files. Alternatively, the user can install the two intermediate certificates (primary and secondary) which are found in the Warrior Bin folder. These give an alternative path back to a trusted root certificate. |
Multifinger caliper:
Removed presentation options for 'Make window bigger' and 'Bulge factor'. Warrior 7 plots will match Warrior 8 plots by setting both of those parameters to 0 in Warrior 7. |